Material Thermal Tester Specifications

Models:

Model 1300

Model 1400

Sample Resistance Range 0.01 K/W - 8 K/W 0.005 K/W - 8 K/W
Resistance Resolution Meas.: 0.0003-0.00002 K/W
Display: 0.001 K/W
Data Accuracy Explicitly Noted
Meas.: 0.0003-0.00001 K/W
Display: 0.001 K/W
Data Accuracy Explicitly Noted
Sample Temperature Range (max.) 20°C - 65 °C (approx.)
(see note below)
20°C - 130°C (approx.)
(see note below)
Pre-heat Temperature Range
(for Phase Change Materials)
35°C - 80°C
Contact Pressure Range Kit 0: 6 – 46 psi ( 40 – 317 kPa)
Kit 1: 5–95 psi (50–650 kPa)
Kit 2: 10–170 psi (100–1150 kPa)
Kit 3: 20–380 psi (200–2600 kPa)
Kit 4 Option: Includes all Kits 0, 1, 2, & 3
Contact Pressure Accuracy Kit 0: +/- 1.3 psi (10 kPa)
Kit 1: +/- 2.5 psi (20 kPa)
Kit 2: +/- 5 psi (40 kPa)
Kit 3: +/- 10 psi (80 kPa)
(see note below)
Sample Size Diameter: 1.3" (33 mm)
Thickness: 0.0" - 0.8 " (0 - 20mm)
(see note below)
Sample Thickness
Electronic-Measurement Range
0.00" - 0.35" (0 - 9 mm)
(other ranges available)
Sample Thickness
Electronic-Measurement Accuracy
+/- 1% of thickness reading
+/- 0.001 (25 micron)
(typical tolerance in hi-accuracy mode)
Weight 42 lbs (19 kg) 47 lbs (21 kg)
Overall Dimensions 22.5" H x 16.5" W x 17" D
58 cm H x 41 cm W x 43 cm  D
Coolant Supply Requirements Flow Rate: 1.5 gal/min (6 liter/min)
Pressure Limit: 50 psi (350 kPa)
Temperature Control: +/- .1°C
Set Point Range: 10°C - 35°C, minimum
Cooling Capacity: 800 watts, minimum
Compressed Air Supply Pressure Minimum: 90 psi (600 kPa)
Particulate Filtration: 10 micron
Supply Voltages 115V-120 VAC
220-240 VAC
100 VAC

 

Notes

Sample Size Note: The recommended sample size is 1.3" (33mm) diameter. Smaller diameter samples sizes can be tested although this requires a custom area adapter and yields test data with degraded accuracy specifications.

Model 1300 Sample Temperature Range Note: The range of sample temperatures depends on many factors, including the the chiller setpoint range and the thermal resistance of the sample. The above specified range assumes the use of the recommended chiller with a sample impedance greater than 0.2K/W. Chiller with higher maximum setpoints, will yield a higher maximum sample-temperature range. Samples with resistances less than 0.2K/W will have a lower maximum sample-temperature range. For a wider sample temperature range, the TIM Tester 1400 is recommended.

Model 1400 Sample Temperature Range Note: The range of sample temperatures depends on many factors, including the the chiller setpoint range and the thermal resistance of the sample. The above specified range assumes the use of the recommended chiller with a sample impedance greater than 0.1K/W. Chiller with higher maximum setpoints, will yield a higher maximum sample-temperature range. Samples with resistances less than 0.1K/W will have a lower maximum sample-temperature range.

Contact Pressure Accuracy Note: The accuracy of the contact pressure control is based on the pressure kit used  the full recommended sample-size.  The accuracy of the commanded-to-actual pressures is approximately +/-3% of full-scale for all pressure kits.  The contact pressure deviation from the commanded contact pressure thus depends on the pressure range kit installed: the smaller the full-span of the kit, the smaller the contact pressure will deviate from the desired contact pressure. Changing kits requires a simple hardware change and software parameter selection.

Installation Requirements

The TIM Tester 1300/1400 requires a number of external facilities for operation. These requirements and the associated linked pages for each are listed below:

  • Recirculating, temperature-controlled chiller
  • PC computer running w/ LCD monitor
    • PC Operating System must be Windows Pro. Not compatible with Windows Enterprise.
  • In-house compressed air supply: 90 psi (600kPA) at near zero volume-flow-rate
  • AC supply for 1000 watts (plus chiller power requirements)
  • TIM Calibration and Reference Sample Package (included with TIM Tester purchase)
  • Complete Plumbing Kit (included with TIM Tester purchase)

Ordering Information

Model 1300 Model 1400
Order number: Model 1300-Kx where "x" is the desired kit number. Order number: Model 1400-Kx where "x" is the desired kit number.
Optional: 3 complete kit sets for user-installation of desired pressure range kit; order "TIM 1300-K4" Optional: 3 complete kit sets for user-installation of desired pressure range kit; order "TIM 1400-K4"

Specify AC Line voltage if other than 120 VAC. Custom orders welcome.

Material Thermal Testers

  • TIM Testers
  • CTE Tester

TIM Testers

  • Thermal Interface Material (TIM) Tester Features
  • TIM 1300/1400 Specifications
  • TIM Technical Information
  • TIM Test Service
  • TIM Case-Study Example

TIM Included Accessories

  • Calibration Instruments and Reference Sample Set
  • Complete Plumbing Kit
  • Sample-Positioning Fixture

TIM Tester Accessories

  • Recirculating Chiller
  • Precision Copper Test Discs for Adhesive Testing
  • Tester Top Enclosure